Fully-automatic Kjeldahl Analyzer LKA-C10 conducts titration and distillation simultaneously so as to neutralize the ammonia gas released which enhance the test efficiency and avoid the overflow of ammonia. It stand with a measuring range from 0.1 to 200 mgN which gives a maximum recovery of ≥ 99.5 %. The operating ambient temperature of the device starts from 10 °C to 35 °C. 8.0-inch LCD touch screen is used to set the distillation time, the amount of diluent, acid liquor and alkali. Diaphragm pump is used to add reagent so that the injure caused by high pressure pump can be neglected. Wireless network modules is installed for realizing remote data transmission to test data processing and report printing.
| Measurement Range | 0.1 to 200 mgN | ||||||||
| Function | Automatic test module of conventional Nitrogen | ||||||||
| Recovery Rate | ≥ 99.5 % | ||||||||
| Sample | Solid ≤ 5 g liquid ≤ 25 ml | ||||||||
| Distillation Time | 3 to 8 min / sample | ||||||||
| Distillation Mode | Conventional distillation mode | ||||||||
| Distillation Power | 375 W to 1500 W | ||||||||
| Condensate Water Consumption | ≥ 1.5 L / min | ||||||||
| Titr1ation precision | 1 | ||||||||
| Repeatability | RSD ≤ 0.5 % | ||||||||
| Stored record | 5000 | ||||||||
| Automatic Function | Automatic sample dilution, addition of acid and alkali, distillation, reaction cup emptying and cleaning; auto correction, calculation and printing. Several conventional methods are equipped. | ||||||||
| Result Determination | Determined by the terminal color | ||||||||
| Safety Protection Function |
|
||||||||
| Optical sensor | RGB programmable optical sensing technology | ||||||||
| Display mode | 8.0-inch LCD touch screen | ||||||||
| Titration mode | High-precision micro-metering pump | ||||||||
| Way of distillation | Distillation and titration are carried out simultaneously | ||||||||
| Steam flow | Adjustable | ||||||||
| Operating Ambient Temperature | 10 °C to 35 °C | ||||||||
| Language | English | ||||||||
| Power | AC 220 V AC ± 10 % 50 Hz | ||||||||
| Rated Power | 1500 W | ||||||||
| External Dimension | 360×460×680 mm | ||||||||
| Communication Mode | (Enhancement Mode) Network Interface RS232 interface / USB interface | ||||||||
| Weight | About 20 kg |
Ammonia gas released is neutralized to avoid the overflow of ammonia gas and it enhance the test efficiency
For improving precision and reducing cleaning work, traditional syringe plunger pump is replaced by a high-precision micro-metering pump
Imported RGB color sensor technology eliminates the disturbance of ambient light and an accurate judgment
Digestion duct, makes it more convenient for users to operate
To neglect the injure caused by high pressure pump, diaphragm pump is used to add reagent
8.0-inch LCD touch screen to set the distillation time, the amount of diluent, acid liquor and alkali
Wireless network modules for remote data transmission, data processing and report printing
ARM processor with built-in Flash chip and equipped with a file system, enables user to create or delete folders or files and store 1000 routine data
All-stage warning system is installed which alters users for any abnormal working condition at any time
Real-time display of titration curve, informs the user about the working condition at any time
Built-in mini printer; to print experimental data according to their need
Air Permeability Tester
Air Shower
Airborne Particle Counters
Alloy Analyzer
Amino Acid Analyzer
Autoclaves
Automatic Glassware Washer
Balances
Ball Mill Machine
Baths and Circulators
Biochemistry Analyzer
Blood Bag Tube Sealer
Blood Collection Monitor
BLOOD THAW MACHINE
Bottle Top Dispenser
Cabinets
Centrifuge
Chillers
Chromatography
CO2 Incubator
Colony Counter
Color Assessment Cabinet
Colorimeters
Dehumidifier
Density Meter
Differential Scanning Calorimeters
Differential Thermal Analyzers
Dispersion Machine
Dosimeter
Drug Detector
Electrophoresis System
Elemental Analyzer
Environmental Monitoring Equipments
ESR Analyzer
Fiber Analysis
Flame Photometer
Flammability Tester
Fluorescence Analyzer
Fluorometer
Freeze Dryers
Freezers
Fume Extractor
Fume Hood
Gel Documentation
Gel Strength Test System
Gene Electroporator
Glassware Drying Cabinet
Handheld Homogenizer
Heating Mantle
HPLC
Hybridization Oven
Hybridization System
Hydrogen Peroxide Generator
Ice Makers
Incubator
IR Carbon Sulphur Analyzer
Jar Testers
Kjeldahl Systems
Lab Refrigerator-Freezer Combination
Laboratory Shakers and Mixers
Laminar Flow Canopy
Laser Theodolite
Latex Stability Tester
Leather Softness Tester
Magnetic Stirrers and Hotplates
Media Dispensing System
Melting Point Apparatus
Metal Detector
Microplate Reader & Washer
Microscope
Microtome
Microwave Digestion System
Milk Analyzers
Moisture Analyzer
Muffle Furnace
Nucleic Acid Purification System
Oil And Grease Analyzer
Opacity Meter
Osmometer
Oven
Oven Incubator
Paraffin Trimmer
Particle Counter
Particle Size Analyzer
Pathology Workstation
Peristaltic Pump
Petroleum Testing Equipment
Pharmaceutical Testing
Plasma Extractor
Plate Sealer
Platelet Agitator and Incubator
Polarimeter
Potentiometric Titrator
Refractometer
Refrigerators
Rotary Evaporator
Safety Containment Cabinets
Sample Concentrator
Scintillation Counter
Semi-automatic Bio-chemistry Analyzer
Slide Dryer
Solar Powered Products
Sound Level Analysis
Soxhlet Apparatus
Spectrometer
Spectrophotometer
Stomacher
Stroboscope
Tachometer
Test Chamber
Testing Instruments
Thermal Cycler
Thermo-Shakers
TOC Analyzer
Tube Furnace
Ultrasonic Cleaner
Ultrasonic Homogenizer
UV Air Sterilizer
UV Analyzer
UV Pass Box
V-shell Blender
Vacuum Filtration Unit
Vacuum Packing machine
Vacuum Pump
Vacuum Pycnometer
Vacuum Spin Coater
Viscometer
Washer Disinfector
Water Distillers
Water Purification System
Water Purifier
Water Testing
Wind Meter (Anemometer)
X-Ray Machine
Labtron produces high performance TKA series of Kjeldahl Analyzer which is designed on classic Kjeldahl nitrogen determination method. Its latest core control system and fully automatic features attracts users worldwide.
Graphite digesters are used to simplify operations and meet the highest safety requirements. It ensure reproducible digestion due to the improved thermal homogeneity and accurate temperature control
Copyright © 2026 Labtron. All rights reserved.