A PHP Error was encountered

Severity: Warning

Message: fopen(/tmp/ci_session0435886b4a5c6bbd7e7fc17e336b5cd128af23ca): failed to open stream: Disk quota exceeded

Filename: drivers/Session_files_driver.php

Line Number: 176

Backtrace:

File: /home/hitechzo/public_html/labtron.online/application/controllers/Home.php
Line: 7
Function: __construct

File: /home/hitechzo/public_html/labtron.online/index.php
Line: 336
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /tmp)

Filename: Session/Session.php

Line Number: 143

Backtrace:

File: /home/hitechzo/public_html/labtron.online/application/controllers/Home.php
Line: 7
Function: __construct

File: /home/hitechzo/public_html/labtron.online/index.php
Line: 336
Function: require_once

HPLC | HPLC system LHLC-A10
labtron.online

HPLC system LHLC-A10

This HPLC system is equipped with high-pressure constant-current pump and UV detector. Pressure pulsation is controlled by diaphragmatic damper in seconds. The UV detectors helps in identification of samples and elutes that are colourless, odourless in nature. There is auto boot detection function available in this HPLC system.

High pressure pump Single pump
Flow rate range 0.001 - 9.999 mL / min (0.001 mL / min increment)
Pressure range ≤ 0.5 MPa (0 - 42 MPa)
Flow rate precision RSD < 0.06 %
Pulsation ≤ 0.1 MPa (flow rate 1 ml / min, Pressure 5 - 10 MPa)
Qualitative analysis RSD 6 ≤ 0.1 % (naphthalene methyl alcohol solvent)
Quantitative repeatability RSD 6 ≤ 0.3 % (naphthalene methyl alcohol solvent)
Flow rate setting error Ss ≤ 2 % (1 mL / min water, 5 - 10 MPa, room temperature)
Mixing accuracy ± 1 %
Mixing precision ± 0.2 %
Size (W × H × D) 450 × 300 × 160 mm
UV Detector
Wavelength range 190 - 680 nm
Flow cell 8 µL
Spectrum band width 8 nm
Baseline noise ≤ ± 0.25 × 10-5 AU (empty cell)
Wavelength accuracy ± 1 nm
Baseline drift ≤ ± 0.4 × 10-4 AU (empty cell)
Wavelength precision < 0.1 nm
Limit of detection 3 × 10-9 g / mL (naphthalene methyl alcohol solvent)
Size (W × H × D) 450 × 300 × 160 mm

  • Limit baseline noise can be ensured using electronic pulse suppression technique

  • High pressure single pump

  • Easy to change gasket ring & automatic washing function for the column

  • User-friendly software for smooth operations

The HPLC has applications in separation of mixture of compounds in chemical analysis, poison analysis, environmental analysis, protein food detection, medicine testing, and polymer analysis.