Fluorescence Spectrophotometer LFS-A12 consist of a high quality 150 W Xenon light source and photoelectric multiplier tube detectors for providing sufficient light intensity signal to detect sensitivity which ranges between 200 nm to 900 nm. Features fluorescence detection limit of ≤ 1×10-10 g/ml and Water Raman peak of S/N ≥ 150. It consists of the following characteristics, namely, high detection sensitivity, fast scanning speed, high dynamic range, fast 3D scanning, etc. The main principles includes measurement of absorption and fluorescence. Absorbance measurements can be taken via one or more wavelengths. The fluorescence unit increases the measuring range by 1000 for detecting DNA.
| Light source | 150 W Xenon lamp |
| Excitation wavelength | 200 nm to 900 nm |
| Emission wavelength | 200 nm to 900 nm |
| Excitation slit | 2 nm, 5 nm, 10 nm, 20 nm |
| Emission slit | 2 nm, 5 nm, 10 nm, 20 nm |
| Wavelength accuracy | ±1.0 nm |
| Wavelength repeatability | ≤ 0.5 nm |
| Signal-to-Noise Ratio | Raman peak of water (P-P): S/N ≥ 150 (10 nm Slit) |
| Detection limit | ≤1×10-10 g/ml (Quinine Sulphate Solution) |
| Linearity | γ ≥ 0.995 |
| Peak repeatability | ≤ 1.5% |
| Stability (10 min) Zero Drift | ±0.3 |
| Stability (10 min) Value Limit | ±1.5% |
| Wavelength scan speed | Multi-speed level, Maximum at 48000 nm/min |
| Photometric value | 0.00 to 10000.00 |
| Data interface | USB 2.0 |
| Maximum power consumption | 200 W |
| Power Source | AC 220 V/50 Hz; 110 V/60 Hz |
| Dimension | 380×445×310 mm |
| Net weight | 12 kg |
| Gross weight | 14 kg |
High sensitivity is fetched from high efficiency optical design and weak signal detection technology
Excitation and emission wavelength range from 200 nm to 900 nm to meet most of the fluorescence analysis
Fluorescence detection limit of ≤ 1×10-10 g/ml and Water Raman peak of S/N ≥ 150
Classic fluorescence spectra and high quality 3D fluorescence spectra can be achieved via high scanning speed at 48000 nm/min
Wide Spectral measurement range is achieved using a double monochromator
Excitation light monitoring system consist of a light dual beam ratio to ensure the fluorescence signal is high and stable
Unstable samples is analysed via built-in optical gate
It is a highly advance structure with fine finishing
Air Permeability Tester
Air Shower
Airborne Particle Counters
Alloy Analyzer
Amino Acid Analyzer
Autoclaves
Automatic Glassware Washer
Balances
Ball Mill Machine
Baths and Circulators
Biochemistry Analyzer
Blood Bag Tube Sealer
Blood Collection Monitor
BLOOD THAW MACHINE
Bottle Top Dispenser
Cabinets
Centrifuge
Chillers
Chromatography
CO2 Incubator
Colony Counter
Color Assessment Cabinet
Colorimeters
Dehumidifier
Density Meter
Differential Scanning Calorimeters
Differential Thermal Analyzers
Dispersion Machine
Dosimeter
Drug Detector
Electrophoresis System
Elemental Analyzer
Environmental Monitoring Equipments
ESR Analyzer
Fiber Analysis
Flame Photometer
Flammability Tester
Fluorescence Analyzer
Fluorometer
Freeze Dryers
Freezers
Fume Extractor
Fume Hood
Gel Documentation
Gel Strength Test System
Gene Electroporator
Glassware Drying Cabinet
Handheld Homogenizer
Heating Mantle
HPLC
Hybridization Oven
Hybridization System
Hydrogen Peroxide Generator
Ice Makers
Incubator
IR Carbon Sulphur Analyzer
Jar Testers
Kjeldahl Systems
Lab Refrigerator-Freezer Combination
Laboratory Shakers and Mixers
Laminar Flow Canopy
Laser Theodolite
Latex Stability Tester
Leather Softness Tester
Magnetic Stirrers and Hotplates
Media Dispensing System
Melting Point Apparatus
Metal Detector
Microplate Reader & Washer
Microscope
Microtome
Microwave Digestion System
Milk Analyzers
Moisture Analyzer
Muffle Furnace
Nucleic Acid Purification System
Oil And Grease Analyzer
Opacity Meter
Osmometer
Oven
Oven Incubator
Paraffin Trimmer
Particle Counter
Particle Size Analyzer
Pathology Workstation
Peristaltic Pump
Petroleum Testing Equipment
Pharmaceutical Testing
Plasma Extractor
Plate Sealer
Platelet Agitator and Incubator
Polarimeter
Potentiometric Titrator
Refractometer
Refrigerators
Rotary Evaporator
Safety Containment Cabinets
Sample Concentrator
Scintillation Counter
Semi-automatic Bio-chemistry Analyzer
Slide Dryer
Solar Powered Products
Sound Level Analysis
Soxhlet Apparatus
Spectrometer
Spectrophotometer
Stomacher
Stroboscope
Tachometer
Test Chamber
Testing Instruments
Thermal Cycler
Thermo-Shakers
TOC Analyzer
Tube Furnace
Ultrasonic Cleaner
Ultrasonic Homogenizer
UV Air Sterilizer
UV Analyzer
UV Pass Box
V-shell Blender
Vacuum Filtration Unit
Vacuum Packing machine
Vacuum Pump
Vacuum Pycnometer
Vacuum Spin Coater
Viscometer
Washer Disinfector
Water Distillers
Water Purification System
Water Purifier
Water Testing
Wind Meter (Anemometer)
X-Ray Machine
Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.
We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.
We manufacture highly precise UV/Vis automatic scanning spectrophotometer with wavelength ranging from 190-1100nm. It can perform quantitative measurement, photometric measurement, spectrum scanning, DNA/Protein analysis. It is in demand for its user-friendly operations
Labtron provides extensive range of visible spectrophotometer LVS series which can operate over a wavelength range of 320-1100nm. It brings unmatched performance with outstanding accuracy and precision.
Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.
Copyright © 2026 Labtron. All rights reserved.