labtron.online

Portable Spectrophotometer LSP-C10

Portable Spectrophotometer LSP-C10 adopts 1000 line precision blazed grating as the spectroscopic element, the silicon photocell array with large photosensitive area as the detector. The full spectrum led with high life as the light source, and the optical resolution is less than 10 nm in the visible light range. Under the condition of d/8 geometric optical illumination recommended by CIE, spectrophotometer can accurately measure the SCI and SCE reflectance data of samples / fluorescent samples. It has stable performance, accurate color measurement and powerful function.

Reflect 8º(diffused illumination, 8 degree viewing angle)
Optical Geometry SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source
Standards ISO7724-1, ASTM E1164, DIN5033 Teil7
Integrating Sphere Size Φ 40 mm
Light Source Combined full spectrum LED light source, UV light source
Spectrophotometric Mode Flat Grating
Sensor Silicon photodiode array (double row 40 groups)
Wavelength Range 400 to 700 nm
Wavelength Interval 10 nm
Semi band Width 10 nm
Measured Reflectance Range 0 to 200%
Measuring Aperture MAV Φ8 mm / Φ10 mm SAV Φ4 mm / Φ5 mm
Specular Component SCI & SCE
Color Space CIE LAB, XYZ, Yxy, LCh, CIE LUV, s-RGB, HunterLab, βxy,DIN Lab99 Munsell (C/2)
Color Difference Formula ΔE×ab, ΔE×uv, ΔE×94, ΔE×cmc(2:1), ΔE×cmc(1:1), ΔE×00, DINΔE99, ΔE (Hunter)
Other Colorimetric Index WI (ASTM E313,CIE/ISO, AATCC, Hunter), YI(ASTM D1925, ASTM 313), Metamerism Index MI, Staining Fastness, Color Fastness, Color Strength, Opacity, 8° Glossiness, 555 tone classification
Illuminant D65, A , C, D50, D55, D75, F1, F2(CWF), F3, F4, F5, F6, F7(DLF), F8, F9, F10(TPL5), F11(TL84), F12(TL83/U30)
Observer Angle 2° / 10°
Measuring Time About 1.5 s (Measure SCI & SCE about 3.2 s)
Repeatability Spectral reflectance: MAV/SCI, Standard deviation within 0.08% (400 nm to 700 nm: within 0.18%) Chromaticity value: MAV/SCI, within ΔE × ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
Inter-instrument Error MAV/SCI, Within ΔE×ab0.15 (Average for 12 BCRA Series II color tiles)
Measurement Mode Single Measurement, Average Measurement(2 to 99 times)
Locating Method Camera Locating, stabilizer cross position
Displayed Data 3.5 inch TFT color LCD, Capacitive Touch Screen
Data Port USB, Bluetooth 4.2
Data Storage Standard 1000 Pcs, Sample 30000 Pcs
Language English
Operating temperature 0 to 40ºC
Operating humidity 0 to 85 %RH
Dimension 129 × 76 × 217 mm
Battery Li-ion battery, 6000 measurements within 8 hours
Weight Approx. 600 g

  • Designed with combined LED light source with high life and low power consumption, including UV / excluding UV

  • Dual optical path system, the optical resolution in the visible range is less than 10 nm

  • It measures the SCI and SCE spectrum of the sample at the same time

  • Accurate spectrum and lab data, used for color matching and accurate color transmission

  • USB / Bluetooth dual communication mode, wider adaptability

  • Large capacity storage space, which can store more than 30000 pieces of test data

  • Camera locating position and Stabilizer cross measurement position

  • PC software has powerful function expansion

Portable Spectrophotometer is used in plastic electronics, paint and coating, textile printing and dyeing, printing paper, automobile, medical treatment, cosmetics and food industries, as well as scientific research institutions and laboratories etc.

Accessories no.Name
1Power Adapter
2User Guide
3PC Software
4USB cable
5White and Black Calibration Cavity
6Protective Cover
7Wrist strap
88 mm flat aperture
98 mm tip aperture
104 mm flat aperture
114 mm tip aperture

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.

We manufacture highly precise UV/Vis automatic scanning spectrophotometer with wavelength ranging from 190-1100nm. It can perform quantitative measurement, photometric measurement, spectrum scanning, DNA/Protein analysis. It is in demand for its user-friendly operations

Labtron provides extensive range of visible spectrophotometer LVS series which can operate over a wavelength range of 320-1100nm. It brings unmatched performance with outstanding accuracy and precision.

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Copyright © 2026 Labtron. All rights reserved.