Table Top Spectrophotometer LTS-A16 works on dual optical path spectrum analysis technology with full wavelength range for color and transmittance measurement. It adopts reflectance D/8° and transmittance D/0° geometry to measure both opaque and transparent materials. Four types of UV modes are used for fluorescence material measurement. Equipped with touch screen rotatable display screen and android operating system. It is ideal used for color measurement in textile, chemical, petroleum, oil industries.
| Wavelength Range | 360 nm to 780 nm |
| Wavelength Pitch | 10 nm |
| Sensor | Silicon Photodiode Array |
| Grating Method | Concave Grating |
| Sphere Diameter | 152 mm |
| Half Band Width | 5 nm |
| Reflectance Range | 0 to 200 % |
| Resolution | 0.0001 |
| Light Source |
Pulse Xenon Lamp LED |
| UV Measurement | Include UV, 400nm cut, 420nm cut, 460nm cut |
| Operating Temperature | 5 ℃ to 40 ℃ |
| Storage Temperature | -20 ℃ to 45 ℃ |
| Relative Humidity | 80 % RH (at 35 ℃) |
| Measurement Time |
SCI/SCE < 2 SCI+SCE < 4s |
| Measurement Aperture |
Reflectance: XLAV Φ30mm LAV 18mm,MAV Φ11mm SAV Φ6mm Transmittance:Φ25mm (Auto aperture size recognition) |
| Viewing Angles | 2° and 10° |
| Transmittance Sample Size |
No limit on sample width and height Thickness ≤ 50mm |
| Repeatability |
XLAV Spectrum Reflectance/Transmittance: standard deviation within 0.1% XLAV Chromaticity value: Standard deviation within ΔE*ab 0.015 * When a white calibration plate is measured 30 x at 5-second intervals after white calibration |
| Inter-Instrument Agreement | XLAV ΔE*ab 0.15 (BCRA Series II, Average measurement of 12 tiles, at 23℃) |
| Illuminants | A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30,DLF,NBF,TL83,TL84 |
| Display | Reflectance and Transmittance graph/value, color value, color difference values, pass/fail, color simulation, color assessment, haze, liquid chromaticity values, color tendency |
| Color Spaces | L*a*b, L*C*h, Hunter Lab, Yxy, XYZ |
| Color Difference | ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc, ΔE*94, ΔE*00, ΔE*ab(hunter),555 shade sort |
| Other Indices | WI(ASTM E313-00,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Stensby),YI(ASTM D1925,ASTM E313-00,ASTM E313-73),Tint(ASTM E313-00),Metamerism index milm, stain fastness, color fastness, ISO brightness, R457, A density, T density, E density, M Density, APHA/Pt-Co/Hazen, Gardner, Saybolt, ASTM color, Haze, Total Transmittance, Opacity, Color Strength |
| Other Functions |
1. Camera to view measurement area 2. Support horizontal, vertical and downward measurement method (need optional accessories to support for downward measurement) 3. Auto humidity and temperature compensation function |
| Illumination/ Viewing System | Reflection: d/8(Diffused illumination, 8 degree viewing) Simultaneous measurement of SCI/SCE (ISO7724/1, CIE No.15, ASTM E1164, ASTM-D1003-07, DIN5033 Teil7,JIS Z8722 Condition C standard) Transmittance d/0(Diffused illumination, 0 degree viewing ) |
| Interface |
USB USB-B RS-232 |
| Screen Size | 7 Inches Touch Screen |
| Storage Memory | 8 GB U Disk for data storage and transfer |
| Power | 12V/3A |
| Dimensions (L × W × H) | 430 × 240 × 260 mm |
| Weight | 10.8 kg |
Dual optical paths spectrum analysis technology
Four type of UV test modes
Compatibility with SCI/SCE measurement system
Adopts D/8 geometry to meet color measurement
Android operating system with rotating 7 inch touch display screen
Open transmittance measurement are without specific sample size
Switchable reflectance apertures
Large storage memory
| No | Accessory name | Remarks |
| 1 | Power Adaptor | |
| 2 | USB Cable | |
| 3 | fixture for transmittance | |
| 4 | U disk | PC software |
| 5 | Black Calibration Cavity | |
| 6 | White and Green Calibration Tile | |
| 7 | 0% Calibration Tile | Measure transmittance |
| 8 | Reflectance Test Support | |
| 9 | 30mm,18mm,11mm and 6mm apertures | |
| 10 | reflectance sample fixture | |
| 11 | Glass Cell | Size: 40 mm × 10mm |
Air Permeability Tester
Air Shower
Airborne Particle Counters
Alloy Analyzer
Amino Acid Analyzer
Autoclaves
Automatic Glassware Washer
Balances
Ball Mill Machine
Baths and Circulators
Biochemistry Analyzer
Blood Bag Tube Sealer
Blood Collection Monitor
BLOOD THAW MACHINE
Bottle Top Dispenser
Cabinets
Centrifuge
Chillers
Chromatography
CO2 Incubator
Colony Counter
Color Assessment Cabinet
Colorimeters
Dehumidifier
Density Meter
Differential Scanning Calorimeters
Differential Thermal Analyzers
Dispersion Machine
Dosimeter
Drug Detector
Electrophoresis System
Elemental Analyzer
Environmental Monitoring Equipments
ESR Analyzer
Fiber Analysis
Flame Photometer
Flammability Tester
Fluorescence Analyzer
Fluorometer
Freeze Dryers
Freezers
Fume Extractor
Fume Hood
Gel Documentation
Gel Strength Test System
Gene Electroporator
Glassware Drying Cabinet
Handheld Homogenizer
Heating Mantle
HPLC
Hybridization Oven
Hybridization System
Hydrogen Peroxide Generator
Ice Makers
Incubator
IR Carbon Sulphur Analyzer
Jar Testers
Kjeldahl Systems
Lab Refrigerator-Freezer Combination
Laboratory Shakers and Mixers
Laminar Flow Canopy
Laser Theodolite
Latex Stability Tester
Leather Softness Tester
Magnetic Stirrers and Hotplates
Media Dispensing System
Melting Point Apparatus
Metal Detector
Microplate Reader & Washer
Microscope
Microtome
Microwave Digestion System
Milk Analyzers
Moisture Analyzer
Muffle Furnace
Nucleic Acid Purification System
Oil And Grease Analyzer
Opacity Meter
Osmometer
Oven
Oven Incubator
Paraffin Trimmer
Particle Counter
Particle Size Analyzer
Pathology Workstation
Peristaltic Pump
Petroleum Testing Equipment
Pharmaceutical Testing
Plasma Extractor
Plate Sealer
Platelet Agitator and Incubator
Polarimeter
Potentiometric Titrator
Refractometer
Refrigerators
Rotary Evaporator
Safety Containment Cabinets
Sample Concentrator
Scintillation Counter
Semi-automatic Bio-chemistry Analyzer
Slide Dryer
Solar Powered Products
Sound Level Analysis
Soxhlet Apparatus
Spectrometer
Spectrophotometer
Stomacher
Stroboscope
Tachometer
Test Chamber
Testing Instruments
Thermal Cycler
Thermo-Shakers
TOC Analyzer
Tube Furnace
Ultrasonic Cleaner
Ultrasonic Homogenizer
UV Air Sterilizer
UV Analyzer
UV Pass Box
V-shell Blender
Vacuum Filtration Unit
Vacuum Packing machine
Vacuum Pump
Vacuum Pycnometer
Vacuum Spin Coater
Viscometer
Washer Disinfector
Water Distillers
Water Purification System
Water Purifier
Water Testing
Wind Meter (Anemometer)
X-Ray Machine
Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.
We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.
We manufacture highly precise UV/Vis automatic scanning spectrophotometer with wavelength ranging from 190-1100nm. It can perform quantitative measurement, photometric measurement, spectrum scanning, DNA/Protein analysis. It is in demand for its user-friendly operations
Labtron provides extensive range of visible spectrophotometer LVS series which can operate over a wavelength range of 320-1100nm. It brings unmatched performance with outstanding accuracy and precision.
Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.
Copyright © 2026 Labtron. All rights reserved.